Smartify

Wiring Reference

Load ratings, wiring diagrams, and compatibility notes for Smartify switches, retrofit relays, dimmers, LED controllers, and shutter modules.

All TAC smart switches and retrofit relays work without a neutral wire — Live and Load only. TOQ panels require neutral.

Load Ratings

DeviceRatingNotes
TAC standard switch (1–6G)10A / 2300W per channelShared L input, separate output per gang
TAC HL heavy-load switch16A / 3680WPumps, geysers, high-draw loads
TAC F fan switch1A / 230WFan speed control only
Retrofit relay 1Ch (standard)4ABehind existing switch, no rewiring
Retrofit relay 1Ch (heavy)40APumps, geysers, HVAC compressors
Retrofit relay 2Ch4A per channel2 independent circuits, 1 module
Retrofit dimmer 1Ch200W resistive / 100W LEDPhase-cut — dimmable loads only
0–10V dimmer—Commercial LED drivers with 0–10V input
Shutter module5A / 1150WAC motors with end-stop protection only
TAC SH shutter switch5APremium wall-switch shutter control

TAC Smart Switches

No neutral required. Each gang has its own output terminal; all share a single L input.

Retrofit Relay

Installs behind the existing wall switch — no rewiring, no new backbox. The existing switch toggles locally; Zigbee overrides it remotely.

Standard (4A) — lighting, fans, general loads. Heavy-duty (40A) — pumps, geysers, AC compressors, high-inrush motors.

Retrofit Dimmer

Phase-cut dimming only. Not compatible with non-dimmable LED drivers, fluorescent fixtures, or motors.

  • Minimum load: 5W
  • Maximum load: 200W resistive / 100W dimmable LED
  • Dimmable LED drivers must be explicitly rated for phase-cut dimming

0–10V Dimmer

For commercial LED drivers with a 0–10V control input (common in offices, retail, hospitality).

LED Controllers

CV-RGB+CCT (Constant Voltage)

For 12V or 24V LED strip lights. Controls RGB colour + warm/cool colour temperature simultaneously.

CC-CCT (Constant Current)

For current-fed LED fixtures and commercial downlights (350 mA / 500 mA / 700 mA).

Shutter / Blind Module

AC motors only. Motor must have built-in end-stop protection — do not use with motors lacking end-stops.

The module detects end-stop via current sensing. Configure travel time in the Zigbee coordinator after installation.

TOQ Touch Panels

TOQ panels replace the existing switch backbox. They require a neutral wire in addition to Live.

Available in 1-gang, 2-gang, and 3-gang backbox form factors.