Smartify
Retrofit Relays & Dimmers

1 Channel Zigbee Retrofit Relay

A single-channel Zigbee switching relay designed to retrofit any standard mechanical switch into a smart switch — no rewiring, no hardware replacement.

1 Channel Zigbee Retrofit Relay

Protocol: Zigbee 3.0 · Type: Switching Relay · SRP: ₹3,000

Works with: Amazon Alexa · Google Home · Siri / Apple HomeKit

For loads above 4A use external relay / SSR / contactor
Requires: Zigbee coordinator or hub

Description

A single-channel Zigbee switching relay designed to retrofit any standard mechanical switch into a smart switch — no rewiring, no hardware replacement.

Installs behind the existing wall switch in a flush box or on DIN rail. Supports direct load switching up to 4A; for loads between 4A and 10A, an external relay, SSR, or contactor is required. Communicates natively over Zigbee 3.0 with full Home Assistant support, and integrates with Matter and Apple HomeKit via a compatible hub.

Specifications

SpecificationValue
Channels1
Max Switching10A
Recommended LoadUp to 4A
InstallationFlush box or DIN rail
CompatibilityHome Assistant (native), Matter & Apple HomeKit (via hub)
Voltage90–250V AC
Max Current10A
Wireless ProtocolZigbee 3.0
Operating Temperature-10°C to +40°C
Max Case Temperature (Tc)+80°C
Wireless Range≤200m (open field)
Dimensions52 × 47 × 18 mm
IP RatingIP20
Installation TypeBehind Switch / DIN Rail

Installation

Requirements

  • Existing wall switch in a flush box (≥ 60mm depth recommended)
  • Live, Neutral, and Load wires in the flush box
  • Zigbee coordinator within range

Turn off the circuit breaker for the affected circuit.

Remove the existing switch plate. The retrofit module sits behind the existing switch — no visible hardware change.

Connect wiring:

  • Live → L input
  • Neutral → N input
  • Load → load output(s)

Fit the module into the flush box. Use DIN rail adapters for panel board installation.

Replace the switch plate.

Restore power. The device will blink — ready to pair.

Pair with your Zigbee coordinator.

Load Limits

  • Standard relay: up to 4A direct. For 4–10A, use an external relay/SSR/contactor.
  • 40A relay: rated for direct high-current switching. Proper cable sizing and circuit protection mandatory.
  • Dimmer modules: resistive and leading-edge dimmable loads only. Not suitable for ceiling fans.

Shutter Module

The shutter module controls motorised curtains, blinds, and shutters:

  • M1, M2 → motor up/down terminals
  • Configure travel time in your coordinator for accurate position reporting.

Ordering

SRP (incl. GST)₹3,000
GST Rate18%
HSN Code85365090